Studio / Contribution

ST 2110 and IP Contribution Monitoring · Seamless Switching

Studio · Contribution

Monitor every ST 2110 and IP contribution flow, and switch seamlessly the moment one fails.

StreamProbe 2110 watches uncompressed and contribution flows 24/7. IPGuardX keeps the on-air path clean with hitless failover.

MonitoringSeamless switching

Two tools, one goal

See transport, timing and content issues as they appear.

Act before the viewer notices, with automatic failover.

StreamProbe 2110 high-bitrate

Up to 100 Gbps

IPGuardX, per instance

Up to 500 switches

Hardware bypass NIC

No single point of failure

01ST 2110 & IP contribution monitoringStreamProbe 2110
Uncompressed & contribution QoS and QoE

StreamProbe 2110

QoS and QoE monitoring of uncompressed ST 2110 and ST 2022-6 flows (SD, HD, UHD), and of the compressed contribution feeds that reach your facility.

ST 2110-20/30/40 and ST 2022-6
ST 2022-7: essences grouped per service, with path differentiation
PTP sync: delay and offset to the Grand Master in ns
SCTE-104 logging on ST 2110-40
Contribution codecs: ProRes, DNxHD, MJPEG, HEVC up to 4K

Discover StreamProbe

IP contribution monitoring: StreamProbe mosaic for uncompressed ST 2110 services

Transport

RTP/FEC, theoretical frame interval, latency, First Packet Time, GAP and Packet Interval Time.

Timing

PTP/RTP offset with hardware NIC timestamping, and per-essence drift.

Content

Freeze, black, silence and loudness compliance (BS.1770, EBU R 128, ATSC A/85), plus format readback.

02Seamless switchingIPGuardX
IPGuardX dashboard: service flow with near-seamless switch and monitoring
Software-based seamless IP switching

IPGuardX

A software-only, media-aware IP switch with automatic failover and real-time stream analysis, on-premises, virtualized or in the cloud.

Hitless stream switching for IP and TS, including SFN redundancy
SafeGateway: VLAN, NAT, SRT/IP conversion and FEC
Customizable criteria: IP, QoS and QoE thresholds
Up to 500 switches per instance, with open REST API
No SPOF: a hardware bypass NIC keeps streams flowing

Discover IPGuardX

Switch on what matters

Each criterion can trigger a changeover, an alarm, or both.

IP layer

Stream presence, RTP packet loss and minimum bitrate.

Transport stream

TR 101 290 priorities 1 and 2, PID and service presence, MIP for DVB-T SFN.

QoE video

Freeze and black-frame detection.

QoE audio

Silence detection and level monitoring (min and max dB).

IP contribution monitoring and protection of the same flow

IPGuardX switches between redundant sources, StreamProbe 2110 watches the flows around it.

IP contribution monitoring diagram: primary and backup sources into the IPGuardX seamless switch, StreamProbe 2110 monitoring, on-air output and alarms

Where IP contribution monitoring is used

IPGuardX

Headends and contribution: OB vans, SNG, satellite, fiber
IPTV and OTT platforms
Satellite operators and teleports
Playout, master control and disaster recovery
Terrestrial SFN feeds (DVB-T, ATSC 3.0, TV 3.0)

StreamProbe 2110

Uptime: real-time supervision and alerting
Fast troubleshooting: network issue or source content error
SCTE-104 control of ad triggers
SLA reporting with quality reports and notifications
03OrderingSoftware licences
ST 2110 / ST 2022-6

StreamProbe 2110

10 Gbps · 25 Gbps

Performance: MacroService View, Slack and Google Chat, 4K QoE

Base licence

IPGuardX Access

Near-seamless changeover for up to 2 switching functions, with ETR 290 level 1/2 and IP criteria.

Software option

IPGuardX Performance

SRT input and output, Seamless TS, SFN and SMPTE 2022-7.

Software option

IPGuardX Ultimate

All Performance features plus QoE criteria for TS over IP.

Capacity packs: IPGuardX switches can be extended by +10 or +50 on each tier.

IP contribution monitoring and seamless switching: frequently asked questions

What is IP contribution monitoring?

IP contribution monitoring checks, around the clock, the flows that reach and leave a studio or head-end over IP: uncompressed ST 2110 and ST 2022-6 flows and compressed contribution feeds. StreamProbe 2110 measures transport (RTP, FEC, GAP), timing (PTP offset, drift) and content (freeze, black, silence, loudness).

Which standards does IP contribution monitoring with StreamProbe 2110 cover?

ST 2110-20/30/40 and ST 2022-6, with ST 2022-7 path differentiation, in SD, HD and UHD (see SMPTE). Contribution codecs include ProRes, DNxHD, MJPEG and HEVC up to 4K.

How does seamless switching complement IP contribution monitoring?

Seamless (hitless) switching moves a service from a failing source to a healthy one without a visible or audible interruption. IPGuardX is a software-only, media-aware IP switch that does this automatically for IP and TS streams, including SFN redundancy for DVB-T, ATSC 3.0 and TV 3.0.

Which IP contribution monitoring criteria can trigger an IPGuardX switch?

IP layer (stream presence, RTP packet loss, minimum bitrate), transport stream (TR 101 290 priorities 1 and 2, PID and service presence, MIP for SFN) and QoE (video freeze and black frames, audio silence and level). Each criterion can trigger a changeover, an alarm, or both.

Does IP contribution monitoring and switching support SRT and SMPTE 2022-7?

Yes. It supports SRT in caller and listener modes with AES encryption and SMPTE 2022-7 protection, plus 1D and 2D FEC, VLAN and NAT as a SafeGateway.

How many IP contribution flows can IPGuardX switch?

Up to 500 switches per instance, expandable with +10 and +50 packs. A hardware bypass NIC keeps streams flowing during a power loss, a hardware fault or maintenance.

Is IP contribution monitoring complementary to seamless switching?

Yes. IPGuardX switches between redundant sources, while StreamProbe 2110 monitors the sources and the output and sends alarms to your supervision tools.

Protect your studio and contribution flows

Talk to the ENENSYS team about monitoring and seamless switching for your facility.

Contact us